Biot-Savart law: Difference between revisions

From Citizendium
Jump to navigation Jump to search
imported>Paul Wormer
m (→‎Laplace's formula: wl to units)
imported>Caesar Schinas
m (Bot: Update image code)
Line 7: Line 7:


==Laplace's formula==
==Laplace's formula==
[[Image:Laplace magnetic.png|right|thumb|250px|Magnetic induction d'''B''' at point '''r''' due to  infinitesimal piece d'''s''' (red) of wire (blue) transporting electric current ''i''. ]]
{{Image|Laplace magnetic.png|right|250px|Magnetic induction d'''B''' at point '''r''' due to  infinitesimal piece d'''s''' (red) of wire (blue) transporting electric current ''i''. }}
The infinitesimal magnetic induction <math>\scriptstyle d\vec{\mathbf{B}} </math> at point <math>\scriptstyle \vec{\mathbf{r}} </math> (see figure on the right) is given by the following formula due to Laplace,
The infinitesimal magnetic induction <math>\scriptstyle d\vec{\mathbf{B}} </math> at point <math>\scriptstyle \vec{\mathbf{r}} </math> (see figure on the right) is given by the following formula due to Laplace,
:<math>
:<math>
Line 17: Line 17:


==Infinite straight conductor==
==Infinite straight conductor==
[[Image:Biot Savart.png|left|thumb|250px|Field '''B''' due to current ''i'' in infinitely long straight wire.]]
{{Image|Biot Savart.png|left|250px|Field '''B''' due to current ''i'' in infinitely long straight wire.}}
Take a straight, infinitely long,  conducting wire transporting the current ''i''.  Historically, this is the case considered by [[Biot]] and [[Savart]]. The magnetic field ''H'' at a distance ''R''
Take a straight, infinitely long,  conducting wire transporting the current ''i''.  Historically, this is the case considered by [[Biot]] and [[Savart]]. The magnetic field ''H'' at a distance ''R''
from the wire is (in SI units)
from the wire is (in SI units)
Line 52: Line 52:


==Magnetic field on axis of circular current==
==Magnetic field on axis of circular current==
[[Image:Axial magnet.png|right|thumb|250px|A current ''i'' runs on circle of radius ''r'' in ''x''-''y'' plane. At a  distance ''R'' of the center there is a magnetic induction '''B''' along the ''z''-axis.]] The Biot-Savart expression can be integrated in [[cylinder coordinates]] for a point ''R'' on the ''z''-axis. This gives (see figure on the right) a  vector parallel to the ''z''-axis of magnitude
{{Image|Axial magnet.png|right|250px|A current ''i'' runs on circle of radius ''r'' in ''x''-''y'' plane. At a  distance ''R'' of the center there is a magnetic induction '''B''' along the ''z''-axis.}} The Biot-Savart expression can be integrated in [[cylinder coordinates]] for a point ''R'' on the ''z''-axis. This gives (see figure on the right) a  vector parallel to the ''z''-axis of magnitude
:<math>
:<math>
B = 2\pi k \frac{i r^2}{(R^2+r^2)^{3/2}}.
B = 2\pi k \frac{i r^2}{(R^2+r^2)^{3/2}}.
Line 62: Line 62:


In the above we wrote ''i'' for the current, which is equal to the current density '''J''' times the cross section ''A'' of the wire. If the current density '''J''' is not constant over the cross section, i.e., '''J''' = '''J'''(<b>r</b>' ), we must use a surface integral over the cross section ''A''. Rather than introducing a surface element, we multiply immediately by d''s'' and obtain an infinitesimal ''volume'' element <math>\scriptstyle  d\mathbf{r}' \equiv dV</math>,  
In the above we wrote ''i'' for the current, which is equal to the current density '''J''' times the cross section ''A'' of the wire. If the current density '''J''' is not constant over the cross section, i.e., '''J''' = '''J'''(<b>r</b>' ), we must use a surface integral over the cross section ''A''. Rather than introducing a surface element, we multiply immediately by d''s'' and obtain an infinitesimal ''volume'' element <math>\scriptstyle  d\mathbf{r}' \equiv dV</math>,  
[[Image:Piece of wire Biot Savart.png|left|thumb|150px|Piece of wire of cross section ''A'' and length <i>d</i>''s'', volume ''d''&thinsp;<b>r'</b> &equiv; ''dV'' = ''A''<i>d</i>''s'' ]]
{{Image|Piece of wire Biot Savart.png|left|150px|Piece of wire of cross section ''A'' and length <i>d</i>''s'', volume ''d''&thinsp;<b>r'</b> &equiv; ''dV'' = ''A''<i>d</i>''s'' }}
:<math>
:<math>
i d\mathbf{s} \rightarrow \iint_{A} \mathbf{J}(\mathbf{r}') d\mathbf{r}',
i d\mathbf{s} \rightarrow \iint_{A} \mathbf{J}(\mathbf{r}') d\mathbf{r}',

Revision as of 09:50, 11 June 2009

This article is developing and not approved.
Main Article
Discussion
Related Articles  [?]
Bibliography  [?]
External Links  [?]
Citable Version  [?]
 
This editable Main Article is under development and subject to a disclaimer.

In physics, more particularly in electrodynamics, the law first formulated by Jean-Baptiste Biot and Félix Savart [1] describes the magnetic induction B (proportional to the magnetic field H) caused by a direct electric current in a wire. Biot and Savart interpreted their measurements by an integral relation. Laplace gave a differential form of their result, which now often is also referred to as the Biot-Savart law, or sometimes as the Biot-Savart-Laplace law. By integrating Laplace's equation over an infinitely long wire, the original integral form of Biot and Savart is obtained.

Ørsted's discovery

The Danish physicist Ørsted noticed in April 1820, while experimenting with the Voltaic pile, an effect of an electric current on a permanent magnet. He wrote a Latin publication which he sent round Europe. François Arago demonstrated the discovery at the French Académie des Sciences (11 September 1820), which inspired Jean-Baptiste Biot and André-Marie Ampère to investigate the effect further. At a meeting of the Académie des Sciences on 30 October 1820, Biot and Savart announced that the magnetic force exerted by a long conductor on a magnetic pole falls off with the reciprocal of the distance and is orientated perpendicular to the wire. Simultaneously they published this in a short note. Laplace generalized their result mathematically.

Laplace's formula

CC Image
Magnetic induction dB at point r due to infinitesimal piece ds (red) of wire (blue) transporting electric current i.

The infinitesimal magnetic induction at point (see figure on the right) is given by the following formula due to Laplace,

where the magnetic induction is given as a vector product, i.e., is perpendicular to the plane spanned by and . The electric current i is constant in time. The piece of the wire contributing to the magnetic induction can be seen as a vector of infinitesimal length ds and with direction tangent to the wire. The constant k depends on the units chosen. In SI units k is the magnetic constant (vacuum permeability) divided by 4π. The magnetic constant μ0 = 4π ×10−7 N/A2 (newton divided by ampere squared). In Gaussian units k = 1/c (one over the speed of light).

If we remember the fact that the vector has dimension length, we see that this equation is an Inverse-square law.

Infinite straight conductor

CC Image
Field B due to current i in infinitely long straight wire.

Take a straight, infinitely long, conducting wire transporting the current i. Historically, this is the case considered by Biot and Savart. The magnetic field H at a distance R from the wire is (in SI units)

       

where in vacuum the magnetic field and the magnetic induction are related by B = μ0H.

In order to prove the expression for H, we write, using R = r sinα (see the figure),

where is a unit vector along , which is perpendicular to the plane spanned by the wire and the vector perpendicular to the wire. Note that if is moved along the wire, all contributions from the segments to the magnetic induction are along this unit vector. Hence, if we integrate over the wire we add up all these contributions, so that

where, by the Pythagorean theorem,

Substitution of y = s / R and y = cotφ = cosφ / sinφ, successively, gives finally,

where i is the current and R is the distance of the point of observation to the wire (length of vector ).

The constant k depends on the choice of electromagnetic units and is μ0/4π = 10−7 henry/m in rationalized SI units. In Gaussian units k = 1/c. This equation gives the original formulation of Biot and Savart.

The SI dimension of B is T (tesla). A field of 1 T corresponds to 10 000 G (gauss).

Magnetic field on axis of circular current

CC Image
A current i runs on circle of radius r in x-y plane. At a distance R of the center there is a magnetic induction B along the z-axis.

The Biot-Savart expression can be integrated in cylinder coordinates for a point R on the z-axis. This gives (see figure on the right) a vector parallel to the z-axis of magnitude

Note that the direction of the electric current i and the magnetic induction B are related according to the right-hand screw rule: the screw is driven into the direction of B and rotated along i. The factor k is μ0/4π for SI units and 1/c for Gaussian units.

Generalized Biot-Savart-Laplace law

From hereon vectors are indicated by bold letters, arrows on top are omitted.

In the above we wrote i for the current, which is equal to the current density J times the cross section A of the wire. If the current density J is not constant over the cross section, i.e., J = J(r' ), we must use a surface integral over the cross section A. Rather than introducing a surface element, we multiply immediately by ds and obtain an infinitesimal volume element ,

CC Image

where we defined the current density J as a vector parallel to the line segment ds and of magnitude J(r'). The volume element has height |ds| and base an infinitesimal surface element of the cross section A. The B-field at point r, due to a volume V = As of the current becomes,

Note that:

where we choose the nabla operator, the gradient, to act on the unprimed coordinates and hence it may be moved outside the integral, giving the following generalized form of the Biot-Savart-Laplace law for the magnetic induction at point r:

Here is the curl and V is a finite volume of the current generating the B-field. The total B-field is obtained by having V encompass all current (integrating over all current).

Consistency with Maxwell equations

The expression for B given in Eq. (1) is a solution of the Maxwell equations with zero displacement current. This is of interest as it confirms the generally accepted notion that the Maxwell equations form a set of postulates for classical electrodynamics. All electrodynamic results, including Biot-Savart's law, must be derivable from them. We will show that the Biot-Savart-Laplace law can indeed be seen as a consequence of the Maxwell postulates, although Biot and Savart made their discovery some forty-five years before Maxwell.

The Helmholtz decomposition of B(r) is,

where

are, respectively, the perpendicular (transverse, divergence-free) and parallel (longitudinal, curl-free) components. The operator acts on unprimed coordinates and ∇' acts on primed coordinates. The pertinent Maxwell's equations are in SI units

Hence

See also

References

  1. J.-B. Biot and F. Savart, Note sur le Magnétisme de la pile de Volta, Annales Chim. Phys. vol. 15, pp. 222-223 (1820), free online version

Further reading:

  • J. D. Jackson, Classical Electrodynamics, 2nd edition, John Wiley, New York (1975).