Magnetic resonance imaging: Difference between revisions
imported>Daniel Mietchen |
imported>Daniel Mietchen (intro rephrased) |
||
Line 1: | Line 1: | ||
{{subpages}} | {{subpages}} | ||
'''Magnetic resonance imaging''' (also known as '''Nuclear Magnetic Resonance imaging''' or as an '''MRI scan''') is a [[non-destructive imaging]] technique with a wide range of applications in the [[materials science]]s and [[life sciences]], including [[diagnostic imaging]] and [[neuroimaging]]. It employs the principle of [[nuclear magnetic resonance]] and is thus, in essence, a variant of [[NMR spectroscopy]] in which the exchange of information with the sample of interest is achieved by radiofrequency pulses at [[isotope]]-specific energy levels. The main difference between MR spectroscopy and MR imaging (the ''N'' is often dropped to avoid confusion with [[nuclear energy]]) is that the static [[magnetic field]] used in the former is supplemented in the latter by | |||
space-encoding magnetic [[field gradient]]s which allow to combine the chemical information (or parts thereof) with spatial information to generate isotope-specific images. | |||
==Classification== | ==Classification== | ||
Line 8: | Line 9: | ||
* [[Magnetic resonance spectroscopy]]<ref>Fisher M, Prichard JW, Warach S. New magnetic resonance techniques for acute ischemic stroke. JAMA. 1995 Sep 20;274(11):908-11. PMID 7674506</ref> | * [[Magnetic resonance spectroscopy]]<ref>Fisher M, Prichard JW, Warach S. New magnetic resonance techniques for acute ischemic stroke. JAMA. 1995 Sep 20;274(11):908-11. PMID 7674506</ref> | ||
* [[Magnetic resonance microscopy]] - concerned with imaging at resolutions around or below about 100µm | * [[Magnetic resonance microscopy]] - concerned with imaging at resolutions around or below about 100µm | ||
* [[Localized spectroscopy]] - combines MR spectroscopy and MR imaging by providing spectroscopic information from specific spatial locations within the sample | |||
* [[Chemical-shift imaging]] - combines MR spectroscopy and MR imaging by providing information about the spatial distribution of spectroscopically visible [[chemical bond]]s within the sample | |||
* [[Cine magnetic resonance imaging]] is primarily used in cardiology. | * [[Cine magnetic resonance imaging]] is primarily used in cardiology. | ||
* [[Diffusion magnetic resonance imaging]] usually uses echo-planar imaging and measures changes in the apparent diffusion coefficient (ADC). | * [[Diffusion magnetic resonance imaging]] usually uses echo-planar imaging and measures changes in the apparent diffusion coefficient (ADC). |
Revision as of 06:06, 16 January 2009
Magnetic resonance imaging (also known as Nuclear Magnetic Resonance imaging or as an MRI scan) is a non-destructive imaging technique with a wide range of applications in the materials sciences and life sciences, including diagnostic imaging and neuroimaging. It employs the principle of nuclear magnetic resonance and is thus, in essence, a variant of NMR spectroscopy in which the exchange of information with the sample of interest is achieved by radiofrequency pulses at isotope-specific energy levels. The main difference between MR spectroscopy and MR imaging (the N is often dropped to avoid confusion with nuclear energy) is that the static magnetic field used in the former is supplemented in the latter by space-encoding magnetic field gradients which allow to combine the chemical information (or parts thereof) with spatial information to generate isotope-specific images.
Classification
- Echo-planar imaging allows much faster acquisition of images.
- Functional magnetic resonance imaging uses echo-planar imaging and measures changes in oxygenation status of hemoglobin in response to specific sensory or motor stimulation.[1][2][3]
- Magnetic resonance angiography
- Magnetic resonance spectroscopy[4]
- Magnetic resonance microscopy - concerned with imaging at resolutions around or below about 100µm
- Localized spectroscopy - combines MR spectroscopy and MR imaging by providing spectroscopic information from specific spatial locations within the sample
- Chemical-shift imaging - combines MR spectroscopy and MR imaging by providing information about the spatial distribution of spectroscopically visible chemical bonds within the sample
- Cine magnetic resonance imaging is primarily used in cardiology.
- Diffusion magnetic resonance imaging usually uses echo-planar imaging and measures changes in the apparent diffusion coefficient (ADC).
Physical principles
In contrast to x-ray computed tomography which is based on the density of electrons in tissues, MRI is based on several properties of protons.[5][6][7][8][9]Atoms with an odd number of protons, such as hydrogen, inherently create a small magnetic field that can be measured, then manipulated by MRI, then measured again as the tissue relaxes after the external field is turned off.[5]
Pulse sequence | Description | Application |
---|---|---|
Standard pulse sequences | ||
Spin echo | Proton density (water) | thoracic imaging |
T1 relaxation time | Spin-lattice (longitudinal) relaxation time. Short repitition time (TR) & echo time (TE) | More solid and less mobile molecules (including lipids, cerebral white matter, yellow bone marrow) are bright. T1 images can be obtained faster. T1 images better display gadolinium contrast medium[7] |
T2 relaxation time | Spin-spin (transverse) relaxation time. Long TR & TE | Water (including CSF, urine, cysts, abscesses) is bright[7] |
Other pulse sequences | ||
DWI (diffusion-weighted imaging) | ||
ADC (apparent diffusion coefficient) | ||
GRE (gradient echo) pulse sequences | Blood flow is bright | |
PWI (perfusion-weighted imaging) |
Interpretation
The accuracy of interpretation depends on the quality of both the MRI machine used and the quality of the radiologist.[10]
References
- ↑ Le Bihan D, Jezzard P, Haxby J, Sadato N, Rueckert L, Mattay V. Functional magnetic resonance imaging of the brain. Ann Intern Med. 1995 Feb 15;122(4):296-303. PMID 7825767
- ↑ Gilman S. Imaging the brain. First of two parts. N Engl J Med. 1998 Mar 19;338(12):812-20. PMID 9504943
- ↑ Gilman S. Imaging the brain. Second of two parts. N Engl J Med. 1998 Mar 26;338(13):889-96. PMID 9516225
- ↑ Fisher M, Prichard JW, Warach S. New magnetic resonance techniques for acute ischemic stroke. JAMA. 1995 Sep 20;274(11):908-11. PMID 7674506
- ↑ 5.0 5.1 Hendee WR, Morgan CJ. Magnetic resonance imaging. Part I--physical principles. West J Med. 1984 Oct;141(4):491-500. PMID 6506686
- ↑ Hendee WR, Morgan CJ. Magnetic resonance imaging. Part II--Clinical applications. West J Med. 1984 Nov;141(5):638-48. PMID 6516335
- ↑ 7.0 7.1 7.2 Edelman RR, Warach S. Magnetic resonance imaging - First of Two Parts. N Engl J Med. 1993 Mar 11;328(10):708-16. PMID 8433731
- ↑ Edelman RR, Warach S. Magnetic resonance imaging - Second of Two Parts. N Engl J Med. 1993 Mar 18;328(11):785-91. PMID 8369029
- ↑ Berger A. Magnetic resonance imaging. BMJ. 2002 Jan 5;324(7328):35. PMID 11777806
- ↑ The Scan That Didn’t Scan - NYTimes.com.