Central venous pressure: Difference between revisions

From Citizendium
Jump to navigation Jump to search
imported>Robert Badgett
imported>Robert Badgett
 
(5 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{subpages}}
{{subpages}}
In physiology, the '''central venous pressure''' is "blood pressure in the central large veins of the body. It is distinguished from peripheral venous pressure which occurs in an extremity."<ref>{{MeSH}}</ref> Various disease states such as [[heart failure]] raise the central venous pressure.
{{TOC|right}}
In physiology, the '''central venous pressure''' is "blood pressure in the central large veins of the body. It is distinguished from peripheral venous pressure which occurs in an extremity."<ref>{{MeSH}}</ref> Various disease states such as [[heart failure]] raise the central venous pressure. It may be approximated in physical examination, especially by [[cardiology|cardiologists]], and its continuous automated measurement is common in [[critical care]].


==Detection of elevated central venous pressure==
==Detection of elevated central venous pressure==
===Physical examination===
===Physical examination===
====Procedure====
====Procedure====
[[Image:Gray558.gif|right|thumb|350px|{{#ifexist:Template:Gray558.gif/credit|{{Gray558.gif/credit}}<br/>|}}The veins of the neck..]]
{{Image|Gray558.gif|right|350px|The veins of the neck..}}
=====Inspection=====
=====Inspection=====
Normal the examiner inspects the internal jugular vein while the patient sits reclined at an angle of 30° to 45°.<ref name="pmid8594245">{{cite journal |author=Cook DJ, Simel DL |title=The Rational Clinical Examination. Does this patient have abnormal central venous pressure? |journal=JAMA |volume=275 |issue=8 |pages=630–4 |year=1996 |pmid=8594245 |doi=10.1001/jama.275.8.630 |issn=}}</ref>. The jugular venous pulse is distinguished from the carotid pulse by the jugular vein showing a biphasic pulsation from 'a wave' and 'a v wave'. The jugular pulse is considered abnormal if its meniscus is 4 or more centimeters above the sternal angle of Louis.
Normal the examiner inspects the internal jugular vein while the patient sits reclined at an angle of 30° to 45°.<ref name="pmid8594245">{{cite journal |author=Cook DJ, Simel DL |title=The Rational Clinical Examination. Does this patient have abnormal central venous pressure? |journal=JAMA |volume=275 |issue=8 |pages=630–4 |year=1996 |pmid=8594245 |doi=10.1001/jama.275.8.630 |issn=}}</ref>. The jugular venous pulse (JVP) is distinguished from the carotid pulse by the jugular vein showing a biphasic pulsation from 'a wave' and 'a v wave'. The jugular pulse is considered abnormal if its meniscus is 4 or more centimeters above the sternal angle of Louis.


Variations on the usual examination include using the external jugular vein<ref name="pmid4698149">{{cite journal |author=Stoelting RK |title=Evaluation of external jugular venous pressure as a reflection of right atrial pressure |journal=Anesthesiology |volume=38 |issue=3 |pages=291–4 |year=1973 |pmid=4698149 |doi= |issn=}}</ref> and examining the patient while the patient is sitting erect at 90°.<ref name="pmid18082526">{{cite journal |author=Sinisalo J, Rapola J, Rossinen J, Kupari M |title=Simplifying the estimation of jugular venous pressure |journal=Am. J. Cardiol. |volume=100 |issue=12 |pages=1779–81 |year=2007 |pmid=18082526 |doi=10.1016/j.amjcard.2007.07.030 |issn=}}</ref> When examining the patient sitting upright, the jugular pulse is considered abnormal if it is visualized above the clavicle.
Variations on the usual examination include using the external jugular vein<ref name="pmid4698149">{{cite journal |author=Stoelting RK |title=Evaluation of external jugular venous pressure as a reflection of right atrial pressure |journal=Anesthesiology |volume=38 |issue=3 |pages=291–4 |year=1973 |pmid=4698149 |doi= |issn=}}</ref> and examining the patient while the patient is sitting erect at 90°.<ref name="pmid18082526">{{cite journal |author=Sinisalo J, Rapola J, Rossinen J, Kupari M |title=Simplifying the estimation of jugular venous pressure |journal=Am. J. Cardiol. |volume=100 |issue=12 |pages=1779–81 |year=2007 |pmid=18082526 |doi=10.1016/j.amjcard.2007.07.030 |issn=}}</ref>
 
The JVP is considered abnormal when the meniscus of the pulse is 4 cm above the sternal angle of Louis when the patient is reclining at 45°. When examining the patient sitting upright, the jugular pulse is considered abnormal if it is visualized above the clavicle. When the pulsation is elevated the patient has jugular venous distention (JVD).


=====Abdominojugular test=====
=====Abdominojugular test=====
Line 16: Line 19:


====Interpretation====
====Interpretation====
The physical examination is more [[specificity (tests)|specific]] than [[sensitivity (tests)|sensitive]] in detecting an elevated central venous pressure according to a [[systematic review]] by the [http://www.sgim.org/clinexam-rce.cfm Rational Clinical Examination] (RCE).<ref name="pmid8594245">{{cite journal |author=Cook DJ, Simel DL |title=The Rational Clinical Examination. Does this patient have abnormal central venous pressure? |journal=JAMA |volume=275 |issue=8 |pages=630–4 |year=1996 |pmid=8594245 |doi=10.1001/jama.275.8.630 |issn=}}</ref>The accuracy of visualizing the meniscus of the jugular pulse at 4 or more centimers above the sternal angle of Louis in the reclining patient according to one study in included in the [[systematic review]] by the RCE:<ref name="pmid2316561">{{cite journal |author=Cook DJ |title=Clinical assessment of central venous pressure in the critically ill |journal=Am. J. Med. Sci. |volume=299 |issue=3 |pages=175–8 |year=1990 |pmid=2316561 |doi= |issn=}}</ref>
 
{| class="wikitable"
|+ Accuracy of the jugular venous distention and [[abdominojugular test]].<ref  name="pmid8594245">{{cite journal|  author=Cook DJ, Simel DL| title=The Rational Clinical Examination. Does  this patient have abnormal central venous pressure? | journal=JAMA |  year= 1996 | volume= 275 | issue= 8 | pages= 630-4 | pmid=8594245 | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=clinical.uthscsa.edu/cite&retmode=ref&cmd=prlinks&id=8594245  }} </ref><ref name="pmid9169900">Review: Subtle clinical findings can detect left-sided heart failure in adults. ACP J Club. 1998 Jan-Feb;128(1):11. Review of [http://pubmed.gov/9169900 PMID 9169900]</ref><ref name="pmid3415106">{{cite journal| author=Ewy GA| title=The abdominojugular test: technique and hemodynamic correlates. | journal=Ann Intern Med | year= 1988 | volume= 109 | issue= 6 | pages= 456-60 | pmid=3415106 | url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=clinical.uthscsa.edu/cite&retmode=ref&cmd=prlinks&id=3415106 }} </ref><ref  name="pmid2182296">{{cite journal |author=Marantz P, Kaplan M, Alderman M |title=Clinical  diagnosis of congestive heart failure in patients with acute dyspnea  |journal=Chest  |volume=97  |issue=4  |pages=776-81  |year=1990  |pmid=2182296}}</ref>
! &nbsp;!!colspan="2"|Increased<br/>central venous pressure!! colspan="2"|Increased<br/>left ventricular end diastolic pressure
|-
! &nbsp;!![[Sensitivity and specificity|Sensitivity]]!![[Sensitivity  and specificity|Specificity]]!![[Sensitivity  and specificity|Sensitivity]]!![[Sensitivity  and specificity|Specificity]]
|-
| Jugular  venous distention|| 48%<ref  name="pmid8594245"/>||88%<ref  name="pmid8594245"/>|| 55% to 65%<ref name="pmid9169900"/>|| 74% to 80%<ref name="pmid9169900"/>
|-
| [[Abdominojugular test]]||24% to 72%<ref  name="pmid3415106"/><ref  name="pmid2182296"/>||96% to 93<ref  name="pmid3415106"/><ref  name="pmid2182296"/>||&nbsp;||&nbsp;
|}
 
 
The physical examination of jugular venous distention is more [[specificity (tests)|specific]] than [[sensitivity (tests)|sensitive]] in detecting an elevated central venous pressure according to a [[systematic review]] by the [http://www.sgim.org/clinexam-rce.cfm Rational Clinical Examination] (RCE).<ref name="pmid8594245">{{cite journal |author=Cook DJ, Simel DL |title=The Rational Clinical Examination. Does this patient have abnormal central venous pressure? |journal=JAMA |volume=275 |issue=8 |pages=630–4 |year=1996 |pmid=8594245 |doi=10.1001/jama.275.8.630 |issn=}}</ref>The accuracy of visualizing the meniscus of the jugular pulse at 4 or more centimers above the sternal angle of Louis in the reclining patient according to one study in included in the [[systematic review]] by the RCE:<ref name="pmid2316561">{{cite journal |author=Cook DJ |title=Clinical assessment of central venous pressure in the critically ill |journal=Am. J. Med. Sci. |volume=299 |issue=3 |pages=175–8 |year=1990 |pmid=2316561 |doi= |issn=}}</ref>
* [[sensitivity (tests)|sensitivity]] = 48%
* [[sensitivity (tests)|sensitivity]] = 48%
* [[specificity (tests)|specificity]] = 88%
* [[specificity (tests)|specificity]] = 88%
Line 23: Line 39:
* [[sensitivity (tests)|sensitivity]] = 77%
* [[sensitivity (tests)|sensitivity]] = 77%
* [[specificity (tests)|specificity]] = 68%
* [[specificity (tests)|specificity]] = 68%
An elevated JVD is associated with reduced prognosis among patients with [[heart failure]].<ref name="pmid11529211">{{cite journal| author=Drazner MH, Rame JE, Stevenson LW, Dries DL| title=Prognostic importance of elevated jugular venous pressure and a third heart sound in patients with heart failure. | journal=N Engl J Med | year= 2001 | volume= 345 | issue= 8 | pages= 574-81 | pmid=11529211
| url=http://www.ncbi.nlm.nih.gov/entrez/eutils/elink.fcgi?dbfrom=pubmed&tool=clinical.uthscsa.edu/cite&email=badgett@uthscdsa.edu&retmode=ref&cmd=prlinks&id=11529211 }}</ref>
In a patient with [[shock (physiology)|shock]] central venous pressure of >7 cm H<sub>2</sub>O suggest [[cardiogenic shock]].<ref name="pmid20945471">{{cite journal| author=Vazquez R, Gheorghe C, Kaufman D, Manthous CA| title=Accuracy of bedside physical examination in distinguishing categories of shock: a pilot study. | journal=J Hosp Med | year= 2010 | volume= 5 | issue= 8 | pages= 471-4 | pmid=20945471 | doi=10.1002/jhm.695 | pmc= | url= }} </ref>


==References==
==References==
<references/>
<references/>

Latest revision as of 12:49, 10 February 2011

This article is a stub and thus not approved.
Main Article
Discussion
Related Articles  [?]
Bibliography  [?]
External Links  [?]
Citable Version  [?]
 
This editable Main Article is under development and subject to a disclaimer.

In physiology, the central venous pressure is "blood pressure in the central large veins of the body. It is distinguished from peripheral venous pressure which occurs in an extremity."[1] Various disease states such as heart failure raise the central venous pressure. It may be approximated in physical examination, especially by cardiologists, and its continuous automated measurement is common in critical care.

Detection of elevated central venous pressure

Physical examination

Procedure

PD Image
The veins of the neck..
Inspection

Normal the examiner inspects the internal jugular vein while the patient sits reclined at an angle of 30° to 45°.[2]. The jugular venous pulse (JVP) is distinguished from the carotid pulse by the jugular vein showing a biphasic pulsation from 'a wave' and 'a v wave'. The jugular pulse is considered abnormal if its meniscus is 4 or more centimeters above the sternal angle of Louis.

Variations on the usual examination include using the external jugular vein[3] and examining the patient while the patient is sitting erect at 90°.[4]

The JVP is considered abnormal when the meniscus of the pulse is 4 cm above the sternal angle of Louis when the patient is reclining at 45°. When examining the patient sitting upright, the jugular pulse is considered abnormal if it is visualized above the clavicle. When the pulsation is elevated the patient has jugular venous distention (JVD).

Abdominojugular test
For more information, see: Abdominojugular test.

The abdominojugular test (AJR) is another method of detecting an abnormal central venous pressure. According to some[5], but not all[6] studies, the AJR is more sensitive than inspection.

Interpretation

Accuracy of the jugular venous distention and abdominojugular test.[2][7][5][6]
  Increased
central venous pressure
Increased
left ventricular end diastolic pressure
  Sensitivity Specificity Sensitivity Specificity
Jugular venous distention 48%[2] 88%[2] 55% to 65%[7] 74% to 80%[7]
Abdominojugular test 24% to 72%[5][6] 96% to 93[5][6]    


The physical examination of jugular venous distention is more specific than sensitive in detecting an elevated central venous pressure according to a systematic review by the Rational Clinical Examination (RCE).[2]The accuracy of visualizing the meniscus of the jugular pulse at 4 or more centimers above the sternal angle of Louis in the reclining patient according to one study in included in the systematic review by the RCE:[8]

If inspecting the patient sitting erect, visualizing the jugular pulse above the clavicle is:[4]

An elevated JVD is associated with reduced prognosis among patients with heart failure.[9]

In a patient with shock central venous pressure of >7 cm H2O suggest cardiogenic shock.[10]

References

  1. Anonymous (2024), Central venous pressure (English). Medical Subject Headings. U.S. National Library of Medicine.
  2. 2.0 2.1 2.2 2.3 2.4 Cook DJ, Simel DL (1996). "The Rational Clinical Examination. Does this patient have abnormal central venous pressure?". JAMA 275 (8): 630–4. DOI:10.1001/jama.275.8.630. PMID 8594245. Research Blogging. Cite error: Invalid <ref> tag; name "pmid8594245" defined multiple times with different content Cite error: Invalid <ref> tag; name "pmid8594245" defined multiple times with different content
  3. Stoelting RK (1973). "Evaluation of external jugular venous pressure as a reflection of right atrial pressure". Anesthesiology 38 (3): 291–4. PMID 4698149[e]
  4. 4.0 4.1 Sinisalo J, Rapola J, Rossinen J, Kupari M (2007). "Simplifying the estimation of jugular venous pressure". Am. J. Cardiol. 100 (12): 1779–81. DOI:10.1016/j.amjcard.2007.07.030. PMID 18082526. Research Blogging.
  5. 5.0 5.1 5.2 5.3 Ewy GA (1988). "The abdominojugular test: technique and hemodynamic correlates". Ann. Intern. Med. 109 (6): 456–60. PMID 3415106[e] Cite error: Invalid <ref> tag; name "pmid3415106" defined multiple times with different content
  6. 6.0 6.1 6.2 6.3 Marantz PR, Kaplan MC, Alderman MH (1990). "Clinical diagnosis of congestive heart failure in patients with acute dyspnea". Chest 97 (4): 776–81. PMID 2182296[e] Cite error: Invalid <ref> tag; name "pmid2182296" defined multiple times with different content
  7. 7.0 7.1 7.2 Review: Subtle clinical findings can detect left-sided heart failure in adults. ACP J Club. 1998 Jan-Feb;128(1):11. Review of PMID 9169900
  8. Cook DJ (1990). "Clinical assessment of central venous pressure in the critically ill". Am. J. Med. Sci. 299 (3): 175–8. PMID 2316561[e]
  9. Drazner MH, Rame JE, Stevenson LW, Dries DL (2001). "Prognostic importance of elevated jugular venous pressure and a third heart sound in patients with heart failure.". N Engl J Med 345 (8): 574-81. PMID 11529211.
  10. Vazquez R, Gheorghe C, Kaufman D, Manthous CA (2010). "Accuracy of bedside physical examination in distinguishing categories of shock: a pilot study.". J Hosp Med 5 (8): 471-4. DOI:10.1002/jhm.695. PMID 20945471. Research Blogging.