Central venous pressure: Difference between revisions

From Citizendium
Jump to navigation Jump to search
imported>Robert Badgett
imported>Robert Badgett
Line 7: Line 7:
[[Image:Gray558.gif|right|thumb|350px|{{#ifexist:Template:Gray558.gif/credit|{{Gray558.gif/credit}}<br/>|}}The veins of the neck..]]
[[Image:Gray558.gif|right|thumb|350px|{{#ifexist:Template:Gray558.gif/credit|{{Gray558.gif/credit}}<br/>|}}The veins of the neck..]]
=====Inspection=====
=====Inspection=====
Normal the examiner inspects the internal jugular vein while the patient sits reclined at an angle of 30° to 45°.<ref name="pmid8594245">{{cite journal |author=Cook DJ, Simel DL |title=The Rational Clinical Examination. Does this patient have abnormal central venous pressure? |journal=JAMA |volume=275 |issue=8 |pages=630–4 |year=1996 |pmid=8594245 |doi=10.1001/jama.275.8.630 |issn=}}</ref>. The jugular venous pulse is distinguished from the carotid pulse by the jugular vein showing a biphasic pulsation from 'a wave' and 'a v wave'. The jugular pulse is considered abnormal if its meniscus is 4 or more centimeters above the sternal angle of Louis.
Normal the examiner inspects the internal jugular vein while the patient sits reclined at an angle of 30° to 45°.<ref name="pmid8594245">{{cite journal |author=Cook DJ, Simel DL |title=The Rational Clinical Examination. Does this patient have abnormal central venous pressure? |journal=JAMA |volume=275 |issue=8 |pages=630–4 |year=1996 |pmid=8594245 |doi=10.1001/jama.275.8.630 |issn=}}</ref>. The jugular venous pulse (JVP) is distinguished from the carotid pulse by the jugular vein showing a biphasic pulsation from 'a wave' and 'a v wave'. The jugular pulse is considered abnormal if its meniscus is 4 or more centimeters above the sternal angle of Louis.


Variations on the usual examination include using the external jugular vein<ref name="pmid4698149">{{cite journal |author=Stoelting RK |title=Evaluation of external jugular venous pressure as a reflection of right atrial pressure |journal=Anesthesiology |volume=38 |issue=3 |pages=291–4 |year=1973 |pmid=4698149 |doi= |issn=}}</ref> and examining the patient while the patient is sitting erect at 90°.<ref name="pmid18082526">{{cite journal |author=Sinisalo J, Rapola J, Rossinen J, Kupari M |title=Simplifying the estimation of jugular venous pressure |journal=Am. J. Cardiol. |volume=100 |issue=12 |pages=1779–81 |year=2007 |pmid=18082526 |doi=10.1016/j.amjcard.2007.07.030 |issn=}}</ref> When examining the patient sitting upright, the jugular pulse is considered abnormal if it is visualized above the clavicle.
Variations on the usual examination include using the external jugular vein<ref name="pmid4698149">{{cite journal |author=Stoelting RK |title=Evaluation of external jugular venous pressure as a reflection of right atrial pressure |journal=Anesthesiology |volume=38 |issue=3 |pages=291–4 |year=1973 |pmid=4698149 |doi= |issn=}}</ref> and examining the patient while the patient is sitting erect at 90°.<ref name="pmid18082526">{{cite journal |author=Sinisalo J, Rapola J, Rossinen J, Kupari M |title=Simplifying the estimation of jugular venous pressure |journal=Am. J. Cardiol. |volume=100 |issue=12 |pages=1779–81 |year=2007 |pmid=18082526 |doi=10.1016/j.amjcard.2007.07.030 |issn=}}</ref>
 
The JVP is considered abnormal when the meniscus of the pulse is 4 cm above the sternal angle of Louis when the patient is reclining at 45°. When examining the patient sitting upright, the jugular pulse is considered abnormal if it is visualized above the clavicle. When the pulsation is elevated the patient has jugular venous distention (JVD).


=====Abdominojugular test=====
=====Abdominojugular test=====

Revision as of 21:51, 8 February 2008

This article is a stub and thus not approved.
Main Article
Discussion
Related Articles  [?]
Bibliography  [?]
External Links  [?]
Citable Version  [?]
 
This editable Main Article is under development and subject to a disclaimer.

In physiology, the central venous pressure is "blood pressure in the central large veins of the body. It is distinguished from peripheral venous pressure which occurs in an extremity."[1] Various disease states such as heart failure raise the central venous pressure.

Detection of elevated central venous pressure

Physical examination

Procedure

PD Image
The veins of the neck..
Inspection

Normal the examiner inspects the internal jugular vein while the patient sits reclined at an angle of 30° to 45°.[2]. The jugular venous pulse (JVP) is distinguished from the carotid pulse by the jugular vein showing a biphasic pulsation from 'a wave' and 'a v wave'. The jugular pulse is considered abnormal if its meniscus is 4 or more centimeters above the sternal angle of Louis.

Variations on the usual examination include using the external jugular vein[3] and examining the patient while the patient is sitting erect at 90°.[4]

The JVP is considered abnormal when the meniscus of the pulse is 4 cm above the sternal angle of Louis when the patient is reclining at 45°. When examining the patient sitting upright, the jugular pulse is considered abnormal if it is visualized above the clavicle. When the pulsation is elevated the patient has jugular venous distention (JVD).

Abdominojugular test
For more information, see: Abdominojugular test.

The abdominojugular test (AJR) is another method of detecting an abnormal central venous pressure. According to some[5], but not all[6] studies, the AJR is more sensitive than inspection.

Interpretation

The physical examination is more specific than sensitive in detecting an elevated central venous pressure according to a systematic review by the Rational Clinical Examination (RCE).[2]The accuracy of visualizing the meniscus of the jugular pulse at 4 or more centimers above the sternal angle of Louis in the reclining patient according to one study in included in the systematic review by the RCE:[7]

If inspecting the patient sitting erect, visualizing the jugular pulse above the clavicle is:[4]

References

  1. Anonymous (2024), Central venous pressure (English). Medical Subject Headings. U.S. National Library of Medicine.
  2. 2.0 2.1 Cook DJ, Simel DL (1996). "The Rational Clinical Examination. Does this patient have abnormal central venous pressure?". JAMA 275 (8): 630–4. DOI:10.1001/jama.275.8.630. PMID 8594245. Research Blogging.
  3. Stoelting RK (1973). "Evaluation of external jugular venous pressure as a reflection of right atrial pressure". Anesthesiology 38 (3): 291–4. PMID 4698149[e]
  4. 4.0 4.1 Sinisalo J, Rapola J, Rossinen J, Kupari M (2007). "Simplifying the estimation of jugular venous pressure". Am. J. Cardiol. 100 (12): 1779–81. DOI:10.1016/j.amjcard.2007.07.030. PMID 18082526. Research Blogging.
  5. Ewy GA (1988). "The abdominojugular test: technique and hemodynamic correlates". Ann. Intern. Med. 109 (6): 456–60. PMID 3415106[e]
  6. Marantz PR, Kaplan MC, Alderman MH (1990). "Clinical diagnosis of congestive heart failure in patients with acute dyspnea". Chest 97 (4): 776–81. PMID 2182296[e]
  7. Cook DJ (1990). "Clinical assessment of central venous pressure in the critically ill". Am. J. Med. Sci. 299 (3): 175–8. PMID 2316561[e]